Templates
Browse the six built-in Miravo templates: a machining line, a water plant, an office building, backup power, district heating and a pharma cleanroom.
A template is a .miravo.yaml file that composes models into a full site. Each built-in template has its own topology, faults and operating conditions. Start one with miravo start and inspect one with miravo templates inspect.
Smart Factory
A discrete production line: machining, wash, press, inspection and utilities.
Water Treatment
A municipal water plant with duty and standby pumps.
Commercial Building
An office tower with rooftop HVAC, chilled water, heating and a standby generator.
Backup Power
A data center backup plant with diesel generation, fuel, cooling and ventilation.
District Heating
A city heat network with gas boilers, trunk pumps and customer substations.
Pharma Cleanroom
A GMP sterile suite with a pressure cascade, make-up air and chilled water.
Compare templates
| Template | Domain | Assets | Models | Protocols | Notable behavior |
|---|---|---|---|---|---|
smart-factory | Discrete manufacturing | 7 | 6 | MQTT, OPC UA, Modbus TCP; every asset | Production line with buffers, shifts, changeovers and OEE signals. Fixed seed. |
water-treatment | Municipal water | 11 | 4 | MQTT, OPC UA, Modbus TCP; scoped per area | Duty and standby pumps. Starts at 30x speed to show wear. |
commercial-building | Office tower | 10 | 6 | MQTT, OPC UA, Modbus TCP; scoped per area | Rooftop HVAC, chilled water, heating and a standby generator. |
backup-power | Data center | 11 | 6 | MQTT, OPC UA, Modbus TCP; scoped per area | Diesel generation with fuel, cooling and ventilation. |
district-heating | City heat network | 12 | 4 | MQTT, OPC UA, Modbus TCP; every asset | Seasonal demand and network pipe delay. Fixed seed. |
pharma-cleanroom | GMP sterile suite | 12 | 6 | MQTT, OPC UA, Modbus TCP; every asset | Pressure cascade, door events and particle counts. Fixed seed. |
Pick by goal
| To show | Start with |
|---|---|
| A full production line with wide asset mix | Smart Factory |
| Pump redundancy, tank levels, process flow balance | Water Treatment |
| Building HVAC, central plant, energy behavior | Commercial Building |
| Standby diesel readiness, fuel, and cooling | Backup Power |
| Seasonal heat demand and network pipe delay | District Heating |
| GMP pressure cascade, door events, particle counts | Pharma Cleanroom |
smart-factory is the default template. The Console Catalog switches to
another template without a restart. Templates with scoped protocols serve each asset
only on the protocols its area, line or asset names.
Related pages
CLI ⭢ miravo start
Run one built-in template or a list of them.
CLI ⭢ templates inspect
Inspect the resolved topology before you run it.
Core ⭢ Templates
.miravo.yaml structure and validation.