Model a standalone induction motor with run state, electrical loading, thermal drift, runtime health, and fault behavior for protocol clients.

AC induction motor model illustration

What it is

A general-purpose three-phase AC induction motor, modeled as a standalone asset. Use it wherever you need a rotating electrical load, such as a fan, pump or conveyor drive, without the hydraulic or process coupling of the more specific models.

Used in

Used in water-treatment (flash mixer), commercial-building (AHU supply fans) and backup-power (hall ventilation fan).

What it tracks

MemberDescription
runningOperating state from the run-command + ramp dynamics.
speed_feedbackRamped rotor speed.
load_factorFraction of rated load the motor is pulling.
current_phase_aSingle-phase current proxy with slip and load coupling.
power_drawElectrical power drawn.
vibration_velocityRMS velocity that grows with bearing and imbalance faults.
winding_temp_u / bearing_temp_deWinding and drive-end bearing temperature. They follow load and rise with faults.
runtime_hoursLifetime counter.
fault_active / active_fault_codeWhether a fault is active, and which one.

Fault modes

  • bearing_defect_inner_race: raises vibration and drive-end bearing temperature, after a 20-minute creep (vibration ×1.25, bearing +1.5 °C).
  • rotor_imbalance: vibration and current rise.
  • winding_insulation: winding temperature climbs and current rises.
  • winding_burnout: end-of-life failure, only in the critical stage (rate 0.01/h, so it almost always fires within the stage's 500 operating hours). A 20-minute precursor (winding temperature +6 °C, current ×1.1), then speed feedback drops to 0 over 15 s and winding temperature jumps 40 °C: running goes false. Production stops. It has no duration: it stays tripped until ResetFault, Maintain or miravo inject --clear.

Key parameters

ParameterDefaultUnit
rated_rpm1750rpm
rated_power_kw7.5kW
rated_voltage400V
rated_current15A
poles4count

Use cases

  • A fan, pump or conveyor drive where the load model comes from the downstream asset.